Description
Overall Dimension of
filter element: 7.50″ dia. x 19.75″ lg.
Designed to filter gear oils and very heavy viscosity oils. For Viscosity of ISO 460 to 1000.
- Removes contaminates as low as 1-micron
- Removes water and particles
- Does not remove or deplete additives
Used For
- Gear Oil
- Engine Oil
- Other high viscosity oil-based lubricants
Capacity & Flow Rate
- Requires 20 Qt./18.9 L. of makeup fluid (housing volume)
- *Ideal sump range from 16-250 Gal./60.6-946.4 L.
Lube 16-22 Gal./60.6-83.3 L.
Gear 151-250 Gal./571.6-946.4 L.
- **Flow rate of Hydraulic filter element: See chart
Specifications
- Beta3=250
- Max operating pressure 80 PSI
- Overall dimensions 19.75” (H), 7.5” (D)
30PSI |
70°F/21.1°C |
104°F/40°C |
150°F/65.6°C |
460 |
.14G/.54L |
.87G/3.3L |
2.94G/11.14L |
680 |
.18G/.68L |
.70G/2.65L |
2.19G/8.30L |
1000 |
N/A |
.22G/.82L |
.99G/3.76L |
**Chart data G—Gallons Per Minute, L-Liters Per Minute
**For high viscosity oils, the oil must be heated in order to obtain flow
Recommended Viscosities
- **ISO: 460, 680, 1000
- SAE: N/A
Notes
- **Flow rates are established using ISO 460-1000 viscosity oils at the standard 40° C/104° F and are subject to vary
- *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment
- Most applications, elements need to be changed between 500-1000 hours for optimal performance, ideally change the element when the flow is half the starting flow or the PSI is double the starting PSI
- The max dirt & water capacities are determined when the flow is reduced by half the original flow (this is the optimal operating condition)