Description
Designed to water
filter element-based fluids, coolants, light glycol mixtures and water-based EDM fluids.
- Removes contaminants as low as 1-micron
- Removes particles from water-based coolants
- Does not remove or deplete additives
Used For
- Water Glycol Fluids
- All Water-Based Lubricants
- Special Oil-Based Application—***Upon Request Capacity & Flow Rate
- Requires 20 Qt./18.9 L. of makeup fluid (housing volume)
- *Ideal sump range from 0-200 Gal./0-757.1 L.
Coolants 51-200 Gal./193.1-757.1 L.
Cutting/Chilling Fluids 0-200 Gal./0-757.1 L.
- **Flow rate range from 0-4.25 GPM/0-16.1 LPM
Specifications
- Beta3=350
- Max operating pressure 80 PSI
- Overall dimensions 19.75” (H), 7.5” (D)
- Used with water-based fluids or, if applicable, petroleum or synthetic fluids
Recommended Viscosities
- Medium thick water-based lubricants equivalent to
ISO: 46, 68, 100, 150
Notes
- **Flow rates of hydraulic filter elements are established using ISO 46-150 viscosity oils at the standard 40° C/104° F and are subject to vary
- *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment
- Most applications, elements need to be changed between 500-1000 hours for optimal performance, ideally change the element when the flow is half the starting flow or the PSI is double the starting PSI
- The max dirt & water capacities are determined when the
flow is reduced by half the original flow (this is the optimal
operating condition)
Reviews