FLOOR MOUNT SYSTEM (T-Stand Single Housing Hyd System)

$5,849.16

Product Size

1000

Service Sump Size

80-270 Gallons

Flow Rate (Gallons Per Minute)

.69-3.25

Oil Viscosity

10, 15, 22, 32, 46, 68, 100, 150

Make-Up Oil Required (Quarts)

20

Filter/Element(s) Part Number Reference

1002, 1004, 642

System Choice

Dedicated

Fluid Type

Hydraulic

Description

Overview

These custom systems can be built to your configurations and specifications. The same Harvard™ Brand quality will reduce waste generated significantly.

Used For

  • Hydraulic Oil
  • Transmissions Oil
  • Other low viscosity oil
  • Use with petroleum or synthetic fluids

Capacity, Sump Size & Flow Rate

  • Requires 20 Qt./18.9 L. of makeup fluid (housing volume)
  • **Sump range: 80-270 Gal./302.83-1022.06 L.
  • *Flow rate range for ISO: 10-32 from .95-3.25 GPM/3.6-12.3 LPM
  • *Flow rate range for ISO 46-150 from .69-1.5 GPM/2.6-5.7 LPM

Other Specifications

  • 5 GPM 65 PSI pump (not fluid flow rate)
  • 3/4 HP 1725 RPM motor (TEFC)
  • 120 volt, single phase
  • Wire directly into shop electricity (Does not come with power cord)
  • PSI switch low limit-12, high limit-65
  • Pressure gauge
  • Push sample port (located on back panel)
  • Plumb directly into shop (Does not come with hoses)
    -Suction port-3/4” female NPT
    -Discharge port–1/2” female NPT
  • Max operating pressure 80 PSI
  • **Optimal running pressure between 20-50 PSI (change filter when
    50-60 PSI)

Overall Dimensions

  • 46” (H) Plus 20” Clearance above to remove filter
  • 17” (W)
  • 21” (D)
  • 153 lbs./69.4 kg. shipping weight

Recommended Elements

  • X1 Model 1002 for ISO: 10, 15, 22, 32
  • X1 Model 1004 for ISO: 46, 68, 100, 150

Notes

  • **Flow rates are established using ISO 10-150 viscosity oils at the standard 40° C/104° F and are subject to vary
  • **Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment
  • Most applications, elements need to be changed between 300-1000 hours for optimal performance, ideally change the element when the flow is half the starting flow or the PSI is double the starting PSI
  • Available in stainless-steel
  • Available option for water-based lubricants
  • Other system configurations are available

Additional information

Product Size

1000

Service Sump Size

80-270 Gallons

Flow Rate (Gallons Per Minute)

.69-3.25

Oil Viscosity

10, 15, 22, 32, 46, 68, 100, 150

Make-Up Oil Required (Quarts)

20

Filter/Element(s) Part Number Reference

1002, 1004, 642

System Choice

Dedicated

Fluid Type

Hydraulic